Membrane Systems & Standards for Retractable Roofs

Retractable roofs represent a relatively innovative structural form. They enable the rapid transformation of a venue between an open-air “field” and an enclosed “arena,” significantly improving the operational environment, maximizing the use of natural daylight, reducing the need for air conditioning, enhancing facility utilization, and promoting energy efficiency and environmental sustainability.

Rigid Structures

Rigid structures achieve roof opening and closing through the translation and rotation of movable roof units. They offer reliable structural performance and high adaptability to various architectural forms. Movable roofs typically employ single-span structural systems—where loads are primarily distributed along the span—though multi-span continuous systems are used in some projects. Trusses, serving as the most straightforward one-way load-bearing systems, are the most common structural choice for movable roofs. Portal-style trusses are utilized when the tracks are positioned on concrete support structures or directly on the ground. Because the horizontal thrust exerted by a movable roof onto the top of its transport carriages significantly impacts the carriages, the drive system, and the supporting structures, efforts should be made to eliminate or minimize any horizontal thrust generated by the roof’s own weight. Edge trusses function both as the perimeter components of the movable roof and as connecting elements between the carriages; reducing the stiffness of these edge trusses can effectively mitigate internal force fluctuations caused by differential deformation among the carriages during operation.

Rigid Foldable Structures

Rigid foldable structures facilitate opening and closing through the relative motion of their individual components, allowing the roof to fold or unfold. For these structures, particular attention must be paid to the specific requirements of hinge assemblies and the building envelope. Rigid foldable movable roofs may consist of multiple trusses connected by hinges. The hinge mechanisms must possess sufficient strength and stiffness to prevent excessive bending deformation, ensuring that the connecting components operate smoothly and reliably during the folding or unfolding process. While a foldable structure functions as a variable system during the folding or unfolding phase, it must be secured via locking mechanisms once the process is complete to form a stable structural system. Flexible Folding Structures

Flexible folding structures achieve the opening and closing of retractable roofs through the deployment and retraction (folding) of membrane materials; they represent one of the earliest forms of retractable architecture. The selection of membrane materials and the design of the membrane structure are critical aspects of these systems. By choosing materials with excellent foldability, the membrane can move freely during deployment and retraction, ensuring structural safety and reliability even under frequent use. The geometry of a flexible folding structure must be designed so that, when the roof is closed, it forms the intended curved surface and fits snugly against the supporting structure. The geometric stiffness—derived from the prestress applied to the cable system and the membrane—is the primary source of the structure’s overall rigidity. Any slackening in the cables or the membrane will reduce this stiffness, potentially leading to intense vibrations under wind loads or even tearing of the membrane. Furthermore, slack in the membrane can cause unsightly wrinkling and impede proper drainage. Therefore, appropriate pretension must be applied to the boundary cables and the membrane to prevent the surface from becoming slack under adverse loading conditions.

A rigid ring beam should be installed along the edge of the opening in the fixed portion of the roof to balance the pretension forces from the cable-membrane system. Depending on the architectural form and boundary conditions, the membrane of a retractable roof is typically stowed toward the center of the roof area.

Supporting Structures

Rigid Supporting Structures

The support conditions for a retractable roof are primarily determined by the building’s function and design. Concrete structures, specialized rail supports, or ground-level rail systems that directly support a retractable roof are classified as “rigid supporting structures.” Conversely, when a retractable roof is supported by a large-span fixed roof structure, the fixed portion is referred to as a “flexible supporting structure.”

For reasons of functional utility and cost-effectiveness, the primary structures of sports venues are frequently constructed using concrete systems. In addition to supporting large-span roof structures, these concrete systems often serve as foundations for spectator stands, offering the advantages of high structural rigidity and economic efficiency. When a movable roof is supported directly by ground-level tracks, dedicated track trenches are typically constructed below the ground elevation. To minimize interference with the use of the site, the drive system for the movable roof can be housed within these trenches. Removable cover plates are placed over the trenches; when the movable roof is stationary, these plates close the trenches, allowing for the unimpeded movement of pedestrians and vehicles.

Flexible Supporting Structure

In recent years, the most common configuration for retractable roofs involves the movable roof being supported directly by a fixed roof structure. The geometry of the fixed roof must align with the operational requirements of the movable roof. Structural forms with high vertical stiffness—such as trusses, or double-layer or multi-layer space frames—are preferred. Loads from the movable roof are transferred to the fixed roof via the tracks; consequently, primary trusses or other reinforcement measures should be implemented in areas where loads are concentrated along the track alignment.

The design of the fixed roof must account for the structure’s self-weight, roofing materials, suspended loads (such as those from gutters, catwalks, lighting, and sound systems), and maintenance loads, as well as the dynamic loads imposed by the movement of the retractable roof. Sufficient stiffness in the fixed roof is essential for the smooth operation of the movable roof; the stiffness of the primary trusses and track-supporting beams must be strictly controlled to ensure that deformations during the movement of the roof remain within specified limits. Furthermore, measures such as pre-cambering should be employed during the design and construction of the fixed roof to ensure high construction precision, which is a prerequisite for the accurate installation of tracks and the subsequent commissioning of the movable roof units.

The enclosure system of a retractable roof must not only fulfill fundamental functions—such as wind and seismic resistance, waterproofing, airtightness, and shading—but must also be capable of accommodating structural deformations. The design should maximize the use of natural daylight, prioritizing materials with high light transmittance to significantly reduce energy consumption for artificial lighting. For retractable roofs that remain closed for extended periods, thermal performance requirements—including thermal insulation—must be addressed to prevent condensation. Additionally, the acoustic impact on the venue should be considered where necessary. Roof enclosures typically utilize lightweight materials such as membrane materials, polycarbonate panels, or metal sheets; for smaller retractable roofs, glass may also be employed.

Technical Standards for Retractable Roofs

Retractable roof projects encompass multiple technical fields—including structural engineering, mechanical systems, and automated control—making them one of the most technologically advanced forms of architecture. There is a relative scarcity of systematic research and specialized literature on the design theory of retractable structures, with key technical insights primarily derived from specific project case studies.

International technical standards and resources concerning retractable roofs include Recommendations for the Design of Air-Supported Structures, Guidelines for the Design of Retractable Roof Structures (with Commentary and Design Data), Guidelines for the Design of Retractable Membrane Structures, and Structural Design of Retractable Roof Structures.

In recent years, following the completion of several large-scale retractable roof projects, my country has continuously explored design methodologies for retractable structures and synthesized practical engineering and construction experience. In 2015, the nation’s first technical standard for such structures—CECS 417:2015 Technical Specification for Retractable Roof Structures—was officially released. To keep pace with the rapid development of retractable roof structures and to meet the requirements for the design, construction, and acceptance of major projects, the industry standard JGJ 442-2019 Technical Standard for Retractable Roof Structures was subsequently issued in 2019.

Newsletter Updates

Enter your email address below and subscribe to our newsletter